Termination and Field Wiring
The 387600310: Top termination uses screws with a captive plate — the plate stays captured in the screw thread, so you don't lose a hardware piece inside a live panel. The bottom termination is closed, meaning this strip is intended for wire entry from the top only; it's a pass-through block, not a feed-through. Terminal screw material is steel with a zinc, clear chromate finish — corrosion-resistant enough for industrial cabinet environments. Wire range is 14-22 AWG solid or stranded. The 20 wire entries (10 circuits × 2 rows) give you two wires per position if you need to daisy-chain power.
The insulator is a black thermoplastic rated UL94 V-0 — the highest common flammability class for enclosed equipment. The strip mounts to chassis or panel via the flanged ends; no DIN rail clip here, so plan for screw-mounting into a backplate or enclosure wall. ROHS3 compliant per current legislation. Lifecycle status is Active — no end-of-life notice, no last-time-buy pressure.