The 59453-131110EDHLF: The ZIF mechanism with slide lock eliminates insertion force on the FPC pads and provides positive retention once the actuator is closed.
Mating Cycle Life and Contact Interface
Rated for 10 mating cycles minimum. For applications requiring frequent reconnection, a higher-cycle connector should be selected.
FPC Cable Compatibility
The bottom-contact design means the FPC pads face downward toward the PCB — verify the cable orientation matches the connector's contact side before assembly. The slide lock actuator clamps the cable without damaging the conductor traces.