SL 70475 IDC Plug, 2 Circuits
Termination and Wire Match
The 24 AWG wire gauge is the specified size for this plug; using a different gauge risks an unreliable gas-tight joint or an open connection. The closed-end housing design prevents the cable from pushing through the back of the connector during assembly, which is a common issue on open-ended IDC parts.
Mating and Housing Fit
The free-hanging (in-line) mount means it is used as a cable-end connector, not a board-mounted header. No secondary locking or TPA is built into the plug body; retention relies on the latch of the mating receptacle housing.