Sealed 2-Way Receptacle Housing for MCON 1.2 / 2.8 Terminals
The sealed construction (no IP rating stated, but the housing is designed to seal when mated with the matching plug and terminal) and the latch holder mean this housing is meant for connections that see engine-bay heat, road spray, or washdown. The -40°C to 130°C range covers cold starts and underhood soak temperatures; derate the terminal current above 85°C per the TE derating curve. Contacts are not included — you must order the correct female socket terminal separately (TE MCON 1.2 or 2.8 series, depending on wire gauge and current requirement).
Lifecycle and Sourcing — Active, No Cross-Reference
There is no official cross-reference or second-source equivalent from TE or another manufacturer that matches the MCON 2-position sealed receptacle form, fit, and function. Confirm the mating plug part number and the specific MCON terminal (1.2 mm or 2.8 mm) before committing the line item.