Skip to main content
TE Connectivity AMP Connectors 170224-2 — Quick-Disconnect Terminals

TE Faston 170224-2 QC Receptacle, 10-15 AWG, 0.250" Tab

MPN170224-2
Active

TE Faston quick-connect receptacle, order code 170224-2, female, 0.250" (6.35mm) tab width, 10-15 AWG, tin-plated brass, non-insulated, crimp termination, free hanging in-line.

$0.2000Ref. price · indicative, final on quote
RoHSROHS3 Compliant
SeriesFaston
New & surplus from a trusted supplier networkAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

170224-2 specifications
ParameterValue
SeriesFaston
MountingFree Hanging (In-Line)
Terminal typeStandard
Wire gauge10-15 AWG
Tab width0.250\" (6.35mm)
Contact materialBrass
GenderFemale
PackageTape & Reel (TR) Cut Tape (CT)
InsulationNon-Insulated
Tab length0.307\" (7.80mm)
TerminationCrimp
Tab thickness0.031\" (0.79mm)
Contact finishTin
Length - overall0.772\" (19.61mm)
Insulation diameter0.118\" ~ 0.197\" (3.00mm ~ 5.00mm)

Product details

Crimp termination and wire range

The 170224-2 is a female quick-connect receptacle from the TE Faston series, accepting 10-15 AWG wire with a crimp termination. It mates to a 0.250" (6.35mm) tab and carries a tin-plated brass contact — the tin finish suits moderate mating cycles in dry environments.

Tab fit and wire-range contrast

The 170224-2 uses a 0.250" tab width and accepts 10-15 AWG wire, while the Utilux 1-1659250-0 uses a 0.248" tab and accepts 17-20 AWG — the 170224-2 handles heavier wire but the tab dimension is nearly identical. The Utilux 1-1627194-4 also shares a 0.250" tab width but accepts 15-18 AWG, making the 170224-2 the heavier-wire choice among these non-insulated crimp receptacles.

Frequently asked questions

What is 170224-2's listed gender?

Female — it is a quick-connect receptacle designed to mate with a male tab.

Will 170224-2 drop into a panel specified around 1-1659250-0 without rewiring?

The 170224-2 uses a 0.250" tab width, while the 1-1659250-0 uses a 0.248" tab — the tab dimension is very close, but the 170224-2 accepts 10-15 AWG versus 17-20 AWG for the peer, so wire gauge compatibility must be verified before substitution.