TE Connectivity AMP Connectors 2-2834006-0 — LED Lighting Connectors

TE 2-2834006-0 Poke-In Receptacle, 2 Pos, 4.00mm Pitch

MPN2-2834006-0
Active

TE Connectivity, Poke-In Wire Receptacle, 2-2834006-0, 2 positions, 0.157" (4.00mm) pitch, 5A/6A, 400V, SMT Right Angle, Tin contacts.

$0.3400Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

2-2834006-0 specifications
ParameterValue
MountingSurface Mount, Right Angle
Connector typeReceptacle, Poke-In Wire
Voltage rating400V
Current rating5A, 6A
Wire gauge18 AWG, 20 AWG, 22 AWG
Operating temperature-40°C ~ 125°C
Housing colorBrown, Yellow
Contact materialCopper Alloy
Housing materialResin
Pitch0.157\" (4.00mm)
StyleBoard to Cable/Wire
PackageTape & Reel (TR) Cut Tape (CT)
TerminationSolder
Contact finishTin
Positions2

Product details

2-Position Poke-In Receptacle, 4.00 mm Pitch, SMT Right-Angle

The 2-2834006-0: Its defining feature is the 0.157" (4.00mm) pitch, which gives enough spacing for 18 AWG to 22 AWG solid or stranded wire to be inserted directly into the contact beam without a separate crimp terminal. The housing is moulded in resin, available in brown or yellow colour variants.

What the 4.00 mm Pitch and 5A Rating Mean for the Fit

The 4.00 mm pitch supports the 400V rating. The 5A per circuit limit applies unless the assembly is in a low-ambient environment. Tin contacts suit moderate mating cycles. The right-angle SMT orientation allows the receptacle to be soldered flat to the board, and the poke-in beam holds the stripped wire directly.

Wire Gauge and Termination Reality

This receptacle accepts 18 AWG, 20 AWG, and 22 AWG wire — the beam geometry is sized for the larger 18 AWG, so 22 AWG seats with less insertion force but also less retention. The Solder termination on the board side is a standard reflow process; the wire side is poke-in, meaning the stripped conductor is pushed past a spring beam that makes electrical contact and provides strain relief. No separate terminal is required, which simplifies the BOM and assembly, but the wire must be stripped to the correct length and the insulation diameter must clear the housing entry.

RoHS compliance is standard for TE's current interconnect portfolio.

Frequently asked questions

What wire gauge does 2-2834006-0 support?

The 2-2834006-0 accepts 18 AWG, 20 AWG, and 22 AWG wire. The poke-in beam is designed for stripped solid or stranded conductors within that range.