TE Connectivity AMP Connectors 282861-3 — Wire-to-Board Headers

TE Buchanan 282861-3 Terminal Block, 3 Pos, 7.62mm, 24 A

MPN282861-3
Active

TE Connectivity Buchanan 282861-3, 3-position terminal block, 0.300" (7.62mm) pitch, 24 A, 300 V, through-hole, rising cage clamp, green housing.

$1.7500Ref. price · indicative, final on quote
RoHSROHS3 Compliant
SeriesBuchanan
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for stock & sourcing questions
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent supplier — new & surplus connector stock· Listing updated Aug 2026

Specifications

282861-3 key specifications
ParameterValue
SeriesBuchanan
MountingThrough Hole
Voltage300 V
Current24 A
Wire gauge12-30 AWG
Wire terminationScrew - Rising Cage Clamp
ColorGreen
Housing materialPolyamide (PA66), Nylon 6/6
Clamp material - platingBrass - Nickel Plated
Screw material - platingBrass - Nickel Plated
Contact material - platingBrass - Tin Plated
Pitch0.300\" (7.62mm)

All specifications

282861-3 additional specifications
ParameterValue
PackageBulk
FeaturesInterlocking (Side)
Screw threadM3
Torque - screw0.79 Nm (7.0 Lb-In)
Number of levels1
Mating orientationHorizontal with Board
Positions per level3

Product details

3-Position Power Block at 7.62 mm Pitch — the 24 A Rating Tells You This Is Not Signal Wiring

The 24 A current rating at 300 V puts this squarely in the power distribution class — it handles motor drives, PSU outputs, or heater loads, not sensor-level signals. The rising cage clamp termination (screw-driven, brass-nickel plated clamp) accepts 12-30 AWG wire and delivers a secure gas-tight connection without requiring a ferrule, which matters when field wiring crews are terminating stranded conductors. The green polyamide (PA66) housing carries an interlocking side feature — you can gang multiple 282861-3 blocks side-by-side without a separate jumper bar, reducing BOM line count for multi-pole assemblies. The M3 screw torque spec of 0.79 Nm (7.0 Lb-In) is the mechanical limit; exceeding it strips the brass threads in the nickel-plated clamp.

What the 24 A / 300 V Rating Means for Your Board Layout

The single-level construction means each of the 3 positions is on the same plane, so wire routing is straightforward for a single circuit group. If the assembly sees repeated thermal cycling or high humidity, the nickel-plated clamp and screw resist corrosion better than bare brass.

Frequently asked questions

What is the wire gauge range for 282861-3?

The rising cage clamp accepts 12-30 AWG wire. The 24 A rating is achievable with 12 AWG; derate for smaller gauges per the temperature rise curve in the product drawing.