4-640441-8 — TE Connectivity AMP Connectors product photo

TE MTA-100 4-640441-8, 18 Position IDC Receptacle

MPN4-640441-8
Active

TE Connectivity MTA-100 receptacle, 4-640441-8, 18 positions, 1 row, 0.100" (2.54mm) pitch, IDC termination, tin contacts, free-hanging right-angle mount, locking ramp, closed end, bulk.

$4.2800Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
  • New & original stockTraceable channels only — no mixed lots, no re-taped reels.
  • Factory packaging where availableSealed reels, trays and bags; cut quantities always stated on the quote.
  • Photo-verified countsEvery line counted and photographed before the box closes.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

4-640441-8 Technical Specifications
ParameterValue
SeriesMTA-100
Wire typeDiscrete or Ribbon Cable
GenderFemale Socket
Mounting typeFree Hanging (In-Line), Right Angle
Connector typeReceptacle
Fastening typeLocking Ramp
Wire gauge24 AWG
Cable terminationIDC
ColorWhite
Pitch0.100\" (2.54mm)
PackageBulk
FeaturesClosed End
Contact finishTin
Rows1
Positions18
Contact finish thickness80.0µin (2.03µm)

Product details

What is the 4-640441-8?

The 0.100" (2.54mm) pitch matches the standard MTA-100 header footprint, and the locking ramp holds the pair together against vibration once mated. The closed-end design blocks debris from entering the back of the connector.

What wire gauge and cable type does it accept?

This IDC receptacle is factory-set for 24 AWG wire — the insulation displacement slot is sized for that gauge. It handles both discrete wires and ribbon cable, so you can run individual conductors or a flat cable bundle through the same connector body. The 24 AWG limitation means 22 AWG or 26 AWG wire will not seat correctly in the IDC slot; stick with the listed gauge for a reliable gas-tight connection.

What is the mating connector?

The 4-640441-8 mates with any standard MTA-100 header of the same pitch and position count — typically a 0.100" (2.54mm) pin header with 18 pins in a single row. No separate terminal crimping is needed on the receptacle side; the IDC termination makes the wire-to-board connection in one press operation.

Frequently asked questions

Where can I buy 4-640441-8?

The 4-640441-8 is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock-holding claim is made here.

Does 4-640441-8 support 22 AWG wire?

No — the IDC slot is sized for 24 AWG wire only. 22 AWG is too large for the insulation displacement slot and will not terminate reliably.