TE 447647-3 SMA Plug Kit, 50 Ohm, 12.4 GHz, RG-174/188/316

MPN447647-3
Obsolete

TE Connectivity SMA plug kit, 50 Ohm, male pin, crimp termination for RG-174/188A/316, DC-12.4 GHz, 0.3 dB insertion loss, 500 mating cycles, nickel-plated brass body, bulk.

$4.2700Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

447647-3 specifications
ParameterValue
MountingFree Hanging (In-Line)
Connector typePlug, Male Pin
Fastening typeThreaded
Frequency - max12.4 GHz
Cable groupRG-174, 188A, 316
Body materialBrass
Housing colorSilver
PackageBulk
Includes3 pcs - 1 Connector, 1 Contact, 1 Ferrule
Impedance50 Ohms
Body finishNickel
Mating cycles500
Insertion loss0.3dB
Number of ports1
Shield terminationCrimp
Contact terminationCrimp

Product details

SMA Plug Kit for RG-174, 188A, 316 Cable

The 447647-3: The kit ships as three pieces: the connector body, the centre contact, and the crimp ferrule, so you have everything in one bag to terminate a cable end.

Cable Fit and Termination

The ferrule is sized for RG-174, RG-188A, and RG-316. Shield and contact termination are both crimp.

Obsolete — Sourcing the 447647-3

TE has marked the 447647-3 as obsolete. No official successor order code appears on record.

Frequently asked questions

What is the replacement for 447647-3?

TE has not published an official direct replacement order code for the 447647-3. The part is obsolete, so the supply channel is surplus inventory and independent distribution. For a new design, any current-production SMA crimp plug for RG-174/188A/316 cable with the same 50 Ohm impedance will mate with the same SMA jack.

Does 447647-3 work with RG58 cable?

No. The 447647-3 ferrule and centre contact are sized for RG-174, RG-188A, and RG-316 cable groups only. RG-58 has a larger dielectric diameter and will not fit the crimp ferrule or centre contact bore.

What tools are needed to install 447647-3?

You need a hex crimp tool with the correct die for the ferrule OD and a separate crimp tool for the centre contact. The shield termination and contact termination are both crimp-style — no solder step. The specific die dimensions depend on the cable jacket and braid diameter for RG-174/188A/316.