It accepts a standard 9-circuit ribbon cable — the IDC termination pierces the insulation in one press operation, making it a production-friendly choice for high-density signal harnesses where individual crimp-and-insert is too slow. The 1.25 A per contact rating and signal-only contact type confirm this is a data or low-current control interconnect, not a power rail.
The 1.25 A per contact rating reflects the IDC termination's current limit.
This receptacle mates with a standard E shell size D-sub plug — the same 9-position, 2-row layout. The 4-40 threaded insert on the housing accepts the mating plug's jackscrew, providing mechanical retention against vibration. Mounting is free-hanging (in-line); the IDC termination exits the rear of the connector, so the assembly floats in the harness rather than being panel-mounted. For panel-mount applications, the threaded insert can be used with a 4-40 screw through the panel.
The shell is steel with tin plating — standard for EMI shielding in a metal-shell D-sub. RoHS compliant per the listing.