It carries signal-level contacts rated 6A each at 125V, making it a fit for interface and control circuits where the pin count matches a standard 15-position BOM line.
6A Per Contact — Signal Duty, Not Bus Power
For control signals, sensor inputs, or low-current interface circuits, 6A leaves headroom.
Grounding Indents and Shell Finish
The steel shell carries grounding indents — raised dimples on the mating face that contact the receptacle shell before the signal pins seat. This establishes shield continuity first, which reduces radiated emissions and protects low-level signals during hot-mate or in high-EMI environments. The tin-plated steel shell also provides a robust ground path when the connector is panel-mounted via the 4-40 threaded inserts.
The termination is through-hole solder, so the contacts are soldered directly into the PCB. The 4-40 threaded inserts in the housing accept jackscrews for secure panel mounting. No crimp tool needed; this is a solder-to-board part.