Skip to main content
T4130012051-000 — TE Connectivity AMP Connectors product photo

T4130012051-000 M12 Receptacle, 5 Pos, Male Pins, 4A, IP67

MPNT4130012051-000
Active

M12 A-coded receptacle, 5-position male pins, 4A per contact, 60V, gold-plated mating surface, solder cup termination, IP67 sealed, panel mount, bulkhead front-side nut.

$7.8400Ref. price · indicative, final on quote
StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
  • New & original stockTraceable channels only — no mixed lots, no re-taped reels.
  • Factory packaging where availableSealed reels, trays and bags; cut quantities always stated on the quote.
  • Photo-verified countsEvery line counted and photographed before the box closes.
  • PayPal buyer protectionPay by T/T, PayPal or Payoneer — card payments covered end to end.

Specifications

T4130012051-000 Technical Specifications
ParameterValue
SeriesM12
Mounting typePanel Mount
Connector typeReceptacle, Male Pins
Fastening typeThreaded
Voltage rating60V
Current rating4A
Ingress protectionIP67 - Dust Tight, Waterproof
Mounting featureBulkhead - Front Side Nut
Operating temperature-40°C ~ 85°C
ColorSilver
Shell materialCopper Alloy
Insert materialPolyamide (PA66), Nylon 6/6
Contact materialCopper Alloy
Primary materialMetal
Material flammability ratingUL94 V-0
PackageBulk
ShieldingUnshielded
OrientationA
TerminationSolder Cup
ApplicationsIndustrial
Shell finishNickel
Positions5
Shell size - insertM12-5
Contact finish - matingGold
Contact finish thickness - mating3.00µin (0.076µm)

Product details

The T4130012051-000 is an M12 A-coded receptacle with male pins, designed for sealed industrial interconnect in sensor, actuator, and fieldbus applications. It carries 5 positions rated 4 A per contact at 60 V, with gold-plated mating surfaces (3.00 µ" thickness) for corrosion resistance over repeated mating cycles. The threaded coupling and IP67 rating — dust-tight and waterproof when mated — suit it for washdown, outdoor, and high-vibration environments where an unsealed connector would fail. Solder cup termination allows field wiring of the cable assembly without a special crimp tool.

What the 4 A per contact rating means for the circuit

4 A per contact at 60 V is typical for M12 signal/power hybrids. Derate above 85 °C per the manufacturer's curve.

Mating and mounting — what fits

This is a panel-mount receptacle with a bulkhead front-side nut — it installs from the front of the panel and tightens with a nut on the back side. The threaded M12 coupling mates with any standard A-coded M12 female plug (5-position female socket). The IP67 seal engages when the plug is fully tightened; the O-ring compresses against the panel face, not the thread. Solder cup termination accepts stranded wire — strip, tin, and solder into the cup. No crimp tool needed, but the joint must be strain-relieved in the cable assembly.

Frequently asked questions

What is the mating connector for T4130012051-000?

It mates with any standard M12 A-coded female plug (5-position female socket) with threaded coupling. The IP67 seal is achieved only when the plug is fully tightened.

What is the pinout of T4130012051-000?

The pinout follows the M12 A-coding standard for 5 positions. The exact wiring assignment depends on the application (e.g., sensor, actuator, or fieldbus); refer to the device or system wiring diagram for the specific signal mapping.