Contacts Not Included — Plan Your BOM
The contact termination is crimp.
Mating Half and Sealing
This receptacle mates with the JST JWPF series pin header (male) plug, which carries the matching latch lock and seal. The JIS C 0920 Grade Level 7 rating is achieved only when the receptacle is mated with the correct plug and the contacts are properly crimped and seated — the seal is at the interface, not a standalone housing feature. For field replacement, the latch lock allows tool-less unmating, but the seal may degrade after repeated cycles; inspect the gasket area before re-mating in a wet environment.