6-Position Receptacle Housing for Crimp-Terminated Harnesses
Panel-mount tabs let you fix the housing to a bulkhead or enclosure wall before terminating the harness.
Mating and Contact Selection
For the female side, you need the matching crimp socket contacts (TE part numbers in the 1-xxxxxx-x range for 22-26 AWG wire). Crimp the contacts with the standard AMPMODU hand tool or a semi-automatic press, then insert into the housing cavities until the retention lance locks. The dual-row arrangement gives 3 positions per row — verify the cavity numbering on the housing face before loading to avoid a crossed circuit.