The 2-5329452-2: It terminates to RG-55, RG-55A, RG-55B, RG-142, RG-142A, RG-142B, and RG-223 cable groups — a standard set for instrumentation, test equipment, and low-power RF transmission up to 2.5 GHz.
Termination Kit — What's in the Box
This is a 4-piece kit: the BNC jack body, one center contact, one ferrule, and one gasket. The shield is terminated by crimp (the ferrule compresses the braid), and the center contact uses a push-on termination to the coax centre conductor.
Obsolete — Sourcing Reality for 2-5329452-2
Can It Be Used with RG-58 Cable?
The listed cable groups are RG-55, 55A, 55B, 142, 142A, 142B, and 223. RG-58 is not in that set. The ferrule and center contact dimensions are sized for the dielectric diameter and braid coverage of the listed cables — RG-58 has a smaller dielectric and different braid density, so the crimp may not achieve the specified retention or impedance. Stick to the listed cable groups for a reliable 50 Ohm termination.